- C-TS 112-V2
- 16CH 100MHz Scaler
・Overview
General Description
C-TS 112-V2 16CH 100MHz Scaler is used for high speed FAST NIM signal of maximum input frequency 100MHz . It has the circuit including 16 channels of independent 24 bits high speed counter . The signal on channel overflowed is output to read line R1 to R16 by CMAC function . It inhibits 16 channels counter at the same time.
Specification
*Number of input :16
*Input signal :FAST NIM
*Maximum input frequency :100MHz
*Minimum input pulse width :5nsec
*Inhibit input : Common of all channels
*Inhibit signal :FAST NIM
*Clear input : Common of all channels
*Clear signal :FAST NIM
*Minimum clear input pulse width :10nsec
*Input connector :LEMO-TYPE (00.250)
*Power supply :+6V=350mA,-6V=500mA
*Packaging :CAMAC Standard single width module
CAMAC Function
N・F(0),A(n) :channel n(=0~15)data read
N・F(1) :reading of overflowed channel
N・F(9) :All channel clear
N・F(25) :Counter increment
CAMAC command
C,Z :Initialize clear
I :Inhibit